YASKAWA E-S Series Product Manual page 235

Ac, dc power supply input and contact commands
Table of Contents

Advertisement

Alarm Number:
Possible Cause
Alarm Name
The wiring is not cor-
rect or there is a faulty
contact in the motor or
encoder wiring.
Operation was per-
formed that exceeded
the overload protec-
tion characteristics.
A.710:
Instantaneous
An excessive load was
Overload
applied during opera-
A.720:
tion because the Ser-
vomotor was not
Continuous
driven due to mechani-
Overload
cal problems.
A failure occurred in
the SERVOPACK.
An unsupported Servo-
motor was selected in
the parameters.
Confirmation
Check the wiring.
Check the motor overload
characteristics and Run
command.
Check the operation refer-
ence and motor speed.
Check the setting of
Pn08A (Motor Selection
Switch).
10.1 Alarm and Warning Displays
10.1.3 Troubleshooting Alarms
Continued from previous page.
Reference
Correction
Correction
Make sure that the Ser-
vomotor and encoder
page 4-11
are correctly wired.
Reconsider the load
and operating condi-
tions. Or, increase the
motor capacity.
Correct the mechanical
problem.
The SERVOPACK may
be faulty. Replace the
SERVOPACK.
Set Pn08A (Motor
Selection Switch) cor-
rectly.
Continued on next page.
for
10
10-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgpss servopackSgmsl servomotor

Table of Contents