YASKAWA E-S Series Product Manual page 266

Ac, dc power supply input and contact commands
Table of Contents

Advertisement

11.1 List of Parameters
11.1.2 List of Parameters
Parameter
No.
PnBAC
PnBAF
11-16
Size
Name
/SEL5 (Program
Step Selection
2
Input 5) Signal
Allocation

n.
X
Signal Usage Method
The /SEL5 (Program Step Selection Input) signal is active when the input signal is
0
ON (closed).
The /SEL5 (Program Step Selection Input) signal is active when the input signal is
1
OFF (open).
2
The /SEL5 (Program Step Selection Input) signal is always active.
3
The /SEL5 (Program Step Selection Input) signal is always inactive.

Signal Terminal Number
n.
X
Same as PnBA0 = n.X.

Reserved parameter (Do not change.)
n.
X

Reserved parameter (Do not change.)
n.X
/S-ON (SERVO
2
ON) Signal Alloca-
tion

n.
X
Signal Usage Method
The system changes to the SERVO ON state (power is supplied) and operation is
0
enabled when the input signal turns ON (closes).
The system changes to the SERVO ON state (power is supplied) and operation is
1
enabled when the input signal turns OFF (opens).
2
The system is always in the SERVO ON state.
3
The system is always in the SERVO OFF state.

n.
X
Signal Terminal Number
Same as PnBA0 = n.X.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
00A0h
00C3h
0000h to
00B0h
00C3h
Continued from previous page.
When
Classi-
Reference
Enabled
fication
After
Setup
page 5-11
restart
After
Setup
page 5-12
restart
Continued on next page.