Parameter
Size
Name
No.
/POUT4
(Program Step
2
Number Output 4)
Signal Allocation
n.
X
Signal Usage Method
PnBC5
n.
X
Signal Terminal Number
Same as PnBC0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/POUT5
(Program Step
2
Number Output 5)
Signal Allocation
n.
X
Signal Usage Method
PnBC6
n.
X
Signal Terminal Number
Same as PnBC0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/WARN
2
(Warning Output)
Signal Allocation
n.
X
Signal Usage Method
PnBC9
n.
X
Signal Terminal Number
Same as PnBC0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
0000h to
00C2h
0
Turn ON (close) the output when program step number output 4 is 1.
1
Turn OFF (open) the output when program step number output 4 is 1.
2
Do not use this signal.
0000h to
00C2h
0
Turn ON (close) the output when program step number output 5 is 1.
1
Turn OFF (open) the output when program step number output 5 is 1.
2
Do not use this signal.
0000h to
00C2h
0
Turn ON (close) the output when an error or warning occurs (error/warning status).
1
Turn OFF (open) the output when an error or warning occurs (error/warning status).
2
Do not use this signal.
11.1.2 List of Parameters
Continued from previous page.
Default
When
Unit
Setting
Enabled
After
−
0050h
restart
After
−
0060h
restart
After
−
0002h
restart
Continued on next page.
11.1 List of Parameters
Classi-
Reference
fication
Setup
page 5-14
Setup
page 5-14
Setup
page 5-14
11-21
11