YASKAWA E-S Series Product Manual page 173

Ac, dc power supply input and contact commands
Table of Contents

Advertisement

7.5 ZONE Outputs
7.5.1 ZONE Table and ZONE Signals
ZONE Table Settings and ZONE Numbers
The relationship between the ZONE table settings and the ZONE numbers is shown below.
• ZONE N ≤ ZONE P
The ZONE signals for the corresponding ZONE number is output if the current value is
between ZONE N and ZONE P, inclusive (the shaded part in the following figure).
• ZONE P ≤ ZONE N
The ZONE signals for the corresponding ZONE number is output if the current value is less
than or equal to ZONE P or greater than or equal to ZONE N (the shaded parts in the follow-
ing figure).
• Duplicated Settings in the ZONE Table
The smaller ZONE number is output.
• ZONE N and ZONE P = 0
The ZONE number is disabled and all ZONE signals will be OFF (0).
• When the Current Value Is Not In Any ZONE
All of the ZONE signals will be OFF (0).
7-46
ZONE N
ZONE P
ZONE P
ZONE N