YASKAWA E-S Series Product Manual page 269

Ac, dc power supply input and contact commands
Table of Contents

Advertisement

Parameter
Size
Name
No.
/INPOSITION
(Positioning
2
Completion
Output)
Signal Allocation

n.
X
Signal Usage Method

n.
X
Signal Terminal Number
PnBC0

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
/POUT0
(Program Step
2
Number Output 0)
Signal Allocation

n.
X
Signal Usage Method
PnBC1

n.
X
Signal Terminal Number
Same as PnBC0 = n.X.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
0000h to
00C2h
0
Turn ON (close) the output when positioning is completed.
1
Turn OFF (open) the output when positioning is completed.
2
Do not use this signal.
0
Output signal from CN1-18.
1
Output signal from CN1-20.
2
Output signal from CN1-21.
3
Output signal from CN1-22.
4
Output signal from CN1-23.
5
Output signal from CN1-24.
6
Output signal from CN1-25.
7
Output signal from CN1-26.
8
Output signal from CN1-27.
9
Output signal from CN1-28.
A
Output signal from CN1-29.
B
Output signal from CN1-30.
C
Output signal from CN1-31.
0000h to
00C2h
0
Turn ON (close) the output when program step number output 0 is 1.
1
Turn OFF (open) the output when program step number output 0 is 1.
2
Do not use this signal.
11.1.2 List of Parameters
Continued from previous page.
Default
When
Unit
Setting
Enabled
After
0000h
restart
After
0010h
restart
Continued on next page.
11.1 List of Parameters
Classi-
Reference
fication
Setup
page 5-13
Setup
page 5-14
11-19
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgpss servopackSgmsl servomotor

Table of Contents