11.1 List of Parameters
11.1.2 List of Parameters
Parameter
No.
PnBA2
PnBA3
PnBA4
11-12
Size
Name
/STOP
(Program Table
2
Operation Stop
Input)
Signal Allocation
n.
X
Signal Usage Method
0
Stop program table operation when the /STOP signal turns ON (closes).
1
Stop program table operation when the /STOP signal turns OFF (opens).
2, 3
Program table operation is not stopped.
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/JOGP
(Forward Jog
2
Input)
Signal Allocation
n.
X
Signal Usage Method
0
Jog forward while the input signal is ON (closed).
1
Jog forward while the input signal is OFF (open).
2, 3
Forward jog operation is not performed.
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/JOGN
(Reverse Jog
2
Input)
Signal Allocation
n.
X
Signal Usage Method
0
Jog in reverse while the input signal is ON (closed).
1
Jog in reverse while the input signal is OFF (open).
2, 3
Reverse jog operation is not performed.
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
−
0020h
00C3h
0000h to
−
0050h
00C3h
0000h to
−
0060h
00C3h
Continued from previous page.
When
Classi-
Reference
Enabled
fication
After
Setup
page 5-10
restart
After
Setup
page 5-11
restart
After
Setup
page 5-11
restart
Continued on next page.