11.1 List of Parameters
11.1.2 List of Parameters
Parameter
No.
PnBC2
PnBC3
PnBC4
11-20
Size
Name
/POUT1
(Program Step
2
Number Output 1)
Signal Allocation
n.
X
Signal Usage Method
0
Turn ON (close) the output when program step number output 1 is 1.
1
Turn OFF (open) the output when program step number output 1 is 1.
2
Do not use this signal.
n.
X
Signal Terminal Number
Same as PnBC0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/POUT2
(Program Step
2
Number Output 2)
Signal Allocation
n.
X
Signal Usage Method
0
Turn ON (close) the output when program step number output 2 is 1.
1
Turn OFF (open) the output when program step number output 2 is 1.
2
Do not use this signal.
n.
X
Signal Terminal Number
Same as PnBC0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/POUT3
(Program Step
2
Number Output 3)
Signal Allocation
n.
X
Signal Usage Method
0
Turn ON (close) the output when program step number output 3 is 1.
1
Turn OFF (open) the output when program step number output 3 is 1.
2
Do not use this signal.
n.
X
Signal Terminal Number
Same as PnBC0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
−
0020h
00C2h
0000h to
−
0030h
00C2h
0000h to
−
0040h
00C2h
Continued from previous page.
When
Classi-
Reference
Enabled
fication
After
Setup
page 5-14
restart
After
Setup
page 5-14
restart
After
Setup
page 5-14
restart
Continued on next page.