8.5.4
Automatically Adjusted Function Settings
You can specify whether to automatically adjust the following functions during autotuning.
Automatic Notch Filters
Normally, set Pn460 to n.1 (Adjust automatically) [default setting].
Vibration will be detected during custom tuning and a notch filter will be adjusted.
Set Pn460 to n.0 (Do not adjust automatically) only if you do not change the setting of
the notch filter before you execute this function.
Parameter
n.
n.
[default setting]
Pn460
n.
0
n.
1
[default setting]
Anti-Resonance Control Adjustment
This function reduces low vibration frequencies, for which the notch filters cannot be used.
Normally, set Pn160 to n.1 (Adjust automatically) [default setting].
Vibration will be detected during custom tuning and anti-resonance control will be automati-
cally adjusted.
Parameter
n.
Pn160
n.
[default setting]
Do not adjust the first stage notch filter auto-
0
matically during execution of custom tuning.
1
Adjust the first stage notch filter automatically
during execution of custom tuning.
Do not adjust the second stage notch filter
automatically during execution of custom tun-
ing.
Adjust the second stage notch filter automati-
cally during execution of custom tuning.
Do not adjust the anti-resonance control auto-
0
matically during execution of custom tuning.
1
Adjust the anti-resonance control automati-
cally during execution of custom tuning.
8.5.4 Automatically Adjusted Function Settings
Function
Function
8.5 Custom Tuning
When Enabled
Classification
Immediately
Tuning
When Enabled
Classification
Immediately
Tuning
8
8-21