Parameter
Size
Name
No.
/DEC
(Homing Deceler-
2
ation Switch Input)
Signal Allocation
n.
X
Signal Usage Method
PnBB2
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/ALM-RST
2
(Alarm Reset)
Signal Allocation
n.
X
Signal Usage Method
PnBB4
2, 3
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/P-CL
(Forward External
2
Torque Limit Input)
Signal Allocation
n.
X
Signal Usage Method
PnBB5
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
0000h to
00C3h
0
Start deceleration during homing when the input signal turns ON (closes).
1
Start deceleration during homing when the input signal turns OFF (opens).
2
Homing deceleration switch is always ON.
3
Homing deceleration switch is always OFF.
0000h to
00C3h
0
Reset alarms when the input signal turns ON (closes).
1
Reset alarms when the input signal turns OFF (opens).
Do not reset alarms. (The signal is disabled.)
0000h to
00C3h
0
Enable the forward external torque limit when the input signal turns ON (closes).
1
Enable the forward external torque limit when the input signal turns OFF (opens).
2
Always enable the forward external torque limit.
3
Always disable the forward external torque limit.
11.1.2 List of Parameters
Continued from previous page.
Default
When
Unit
Setting
Enabled
After
−
0003h
restart
After
−
0040h
restart
After
−
0003h
restart
Continued on next page.
11.1 List of Parameters
Classi-
Reference
fication
Setup
page 5-12
Setup
page 5-12
Setup
page 5-12
11-17
11