Parameter
Size
Name
No.
/HOME
2
(Homing Input)
Signal Allocation
n.
X
Signal Usage Method
PnBA5
2, 3
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/PGMRES
(Program Table
2
Operation Reset
Input)
Signal Allocation
n.
X
Signal Usage Method
PnBA6
2, 3
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
/SEL0
(Program Step
2
Selection Input 0)
Signal Allocation
n.
X
Signal Usage Method
PnBA7
n.
X
Signal Terminal Number
Same as PnBA0 = n.X.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
0000h to
00C3h
0
Start homing when the input signal turns ON (closes).
1
Start homing when the input signal turns OFF (opens).
Homing is not started.
0000h to
00C3h
0
Turn ON (close) the /PGMRES signal to reset and cancel program table operation.
1
Turn OFF (open) the /PGMRES signal to reset and cancel program table operation.
Program table operation is not reset.
0000h to
00C3h
The /SEL0 (Program Step Selection Input) signal is active when the input signal is
0
ON (closed).
The /SEL0 (Program Step Selection Input) signal is active when the input signal is
1
OFF (open).
2
The /SEL0 (Program Step Selection Input) signal is always active.
3
The /SEL0 (Program Step Selection Input) signal is always inactive.
11.1.2 List of Parameters
Continued from previous page.
Default
When
Unit
Setting
Enabled
After
−
0030h
restart
After
−
0040h
restart
After
−
0050h
restart
Continued on next page.
11.1 List of Parameters
Classi-
Reference
fication
Setup
page 5-11
Setup
page 5-11
Setup
page 5-11
11-13
11