Radar level gauge
Hide thumbs Also See for Rosemount 5900S:
Table of Contents

Advertisement

Reference Manual
00809-0100-5900
A.10

Rosemount 5900S with horn antenna

Operating temperature in tank
Max. +180 °C (+356 °F)
Measuring range
0.8 to 20 m (2.6 to 65 ft) below flange.
Possibility to measure 0.5 to 30 m (1.6 to 100 ft). Accuracy may be reduced. For longer
measuring range, consult your local representative.
Pressure range
-0.2 to 2 bar (-2.9 to 29 psig)
Material exposed to tank atmosphere
Antenna and flange: Material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE
O-ring: Viton
Antenna dimension
175 mm (7 in.)
Nozzle diameter
Minimum 200 mm (8 in.)
Tank connection
The flange can be horizontal or 4° inclined for installation close to the tank wall.
The horizontal flange is used when highest accuracy and reliability is required. The 4°
inclined version can be used to maintain high accuracy when the gauge is installed close to
the tank wall.
A.11

Rosemount 5900S with still-pipe array antenna

Operating temperature in tank
-40 to 120 °C (-40 to 248 °F)
Measuring range
0.8 to 30 m (2.6 to 100 ft) below flange.
Possibility to measure 0.5 to 40 m (1.6 to130 ft). Accuracy may be reduced. For longer
measuring range, consult your local representative.
Pressure range
Fixed version: -0.2 to 2 bar (-2.9 to 29 psig) at 20 °C (68 °F).
Hinged hatch version: -0.2 to 0.5 bar (-2.9 to 7.2 psig) for 5 to 8-in. pipes.
Rosemount 5900S Radar Level Gauge
®
Specifications and reference data
September 2019