Figure 3-20: Example of a Tankbus Connection for a Single Tank
A. Tankbus length up to 1000 meter depending on number of devices and cable type
B. Rosemount 2410 Tank Hub with intrinsically safe power supply, integrated power
C. Rosemount 2230 Display
D. Tankbus
E. IS Analog Input (Secondary bus)
F. Rosemount 5900S Radar Level Gauge
G. Rosemount 2240S Multi-input Temperature Transmitter
H. Built-in terminator enabled on the last device
I. Rosemount 3051S Pressure Transmitter
The maximum distance between the tank hub and the field devices on the tank depends
on the number of devices connected to the Tankbus and the quality of cables.
See chapter "Electrical Installation" in the Rosemount 2410 Tank Hub
for more information about cable selection, power budget, the Tankbus, and more
examples on how to install systems that include the Rosemount 2410 Tank Hub.