Emerson Rosemount 5900S Reference Manual page 264

Radar level gauge
Hide thumbs Also See for Rosemount 5900S:
Table of Contents

Advertisement

Product Certifications
September 2019
B.16.2
Europe
IA ATEX FISCO
Certificate
Standards
Markings
FISCO
parameters
Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90V transient suppressor, it is incapable
2. The enclosure may be made of aluminum alloy and given a protective polyurethane
B.16.3
International
IG IECEx FISCO
Certificate
Standards
Markings
FISCO
parameters
Special Conditions for Safe Use (X):
1. If the equipment is fitted with an optional 90V transient suppressor, it is incapable
2. The enclosure may be made of aluminum alloy and given a protective polyurethane
3. The equipment contains thin wall diaphragms. The installation, maintenance and
264
Baseefa08ATEX0129X
EN60079-0:2012+A11:2013, EN60079-11:2012
II 1 G Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)
Ui
Ii
17.5V
380 mA
of withstanding the 500V isolation from earth test and this must be taken into
account during installation.
paint finish; however care should be taken to protect it from impact and abrasion
when located in Zone 0.
IECExBAS08.0045X
IEC60079-0:2011, IEC60079-11:2011
Ex ia IIC T4 Ga (-60°C ≤ Ta ≤ +60°C)
Ui
Ii
17.5V
380 mA
of withstanding the 500V isolation from earth test and this must be taken into
account during installation.
paint finish; however care should be taken to protect it from impact and abrasion
when located in Zone 0.
use shall take into account the environmental conditions to which the diaphragms
will be subjected. The manufacturer's instructions for installation and maintenance
shall be followed in detail to assure safety during its expected lifetime.
Pi
Ci
5.32 W
0 µF
Pi
Ci
5.32 W
0 nF
Reference Manual
00809-0100-5900
Li
0 mH
Li
0 µH
Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents