Emerson Rosemount 5900S Reference Manual page 42

Radar level gauge
Hide thumbs Also See for Rosemount 5900S:
Table of Contents

Advertisement

Installation
September 2019
Figure 3-11: Installation of Verification Pin and Inclination Requirements for Flange
and Still-pipe
A.
1000 < L < 2500 mm (39 < L < 98 in.).
Recommended: 1200 mm (47 in.)
B.
Min. 200 mm (8 in.) from Verification pin to
product
C.
Hole for Verification Pin; Ø 20 mm.
D. Holes for density equalization; Ø 20 mm
(3/4 in.)
E.
500 mm (20 in.)
F.
Mark on still-pipe flange
42
G. The Verification Pin is directed towards the
bolt hole at the pipe flange marking.
H. Bolt hole
I.
Align Verification Pin and bolt hole within
1°.
J.
Maximum 1°
K.
Maximum 0.5°