NOTICE
Read this manual before working with the product. For personal and system safety, and for optimum product performance, make
sure you thoroughly understand the contents before installing, using, or maintaining this product.
For equipment service or support needs, contact your local Emerson Automation Solutions/Rosemount Tank Gauging
representative.
Spare Parts
Any substitution of non-recognized spare parts may jeopardize safety. Repair, e.g. substitution of components etc, may also
jeopardize safety and is under no circumstances allowed.
Rosemount Tank Radar AB will not take any responsibility for faults, accidents, etc caused by non-recognized spare parts or any
repair which is not made by Rosemount Tank Radar AB.
Specific ETSI Requirements (Europe)
The Rosemount 5900S is required to be installed at a permanent fixed position at a closed (not open) metallic tank or reinforced
concrete tank, or similar enclosure structure made of comparable attenuating material. Flanges and attachments of the
Rosemount 5900S equipment shall provide the necessary microwave sealing by design.
Manholes or connection flanges at the tank shall be closed to ensure a low-level leakage of the signal into the air outside the tank.
Installation and maintenance of the Rosemount 5900S equipment shall be performed by professionally trained individuals only.
Specific FCC Requirements (USA)
Rosemount 5900S generates and uses radio frequency energy. If it is not installed and used properly, that is, in strict accordance
with the manufacturer´s instructions, it may violate FCC regulations on radio frequency emission.
Rosemount TankRadar 5900S has been FCC certified under test conditions which assume a metallic tank.
Specific IC Requirements (Canada)
Radio approvals for this device apply for installation in complete enclosed container to prevent unwanted RF emission. In open air
application site license is required. Installation shall be done by trained installers, in compliance with the manufacturer's
instructions.
The use of this device is on a "no-interference, no-protection" basis. That is, the user shall accept operations of high-powered radar
in the same frequency band which may interfere with or damage this device. Devices found to interfere with primary licensing
operations will be required to be removed at the user's expense.
Low Emission of Microwave Radiation
The microwave radiation emitted by a Rosemount 5900S radar level gauge is very low compared to limits given by the Rec.
1999/519/EC (much less than 0.1 mW). No additional safety measures are needed.
CAUTION
The products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualified
products in applications that require nuclear-qualified hardware or products may cause inaccurate readings. For information on
Rosemount nuclear-qualified products, contact your local Emerson Sales Representative.
WARNING
WARNING - Substitution of components may impair Intrinsic Safety.
AVERTISSEMENT - La substitution de composants peut compromettre la sécurité intrinsèque.
WARNING - To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.
AVERTISSEMENT - Ne pas ouvrir en cas de presence d'atmosphere explosive.