4.12

Analog Output block

The Rosemount 5900S is supplied with two pre-configured Analog Output (AO) blocks
according to
Output block
CHANNEL
Select the channel that corresponds to the desired sensor measurement:
Table 4-9: AO Block Channels for the Rosemount 5900S
AO Block Parameter
Vapor Temperature
Pressure
User Defined
Tank Temperature
Table 4-10: Factory Supplied AO Blocks for the Rosemount 5900S
AO Block
1
2
XD_SCALE
The XD_SCALE includes three parameters: 0%, 100%, and engineering units. Set the
XD_SCALE engineering unit to represent the unit for the AO block channel value.
Rosemount 5900S Radar Level Gauge
Table
4-10. The block configuration can be changed if needed. See
for more information.
TB Channel Value
7
8
9
10
Channel
CHANNEL_VAPOR_TEMPERAT
URE
CHANNEL_PRESSURE
Process Variable
CHANNEL_VAPOR_TEMPERATURE
CHANNEL_PRESSURE
CHANNEL_USERDEFINED
CHANNEL_TANK_TEMPERATURE
Units
deg C
bar
Configuration
September 2019
Analog
147

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents