Emerson Rosemount 5900S Reference Manual page 52

Radar level gauge
Hide thumbs Also See for Rosemount 5900S:
Table of Contents

Advertisement

Installation
September 2019
Procedure
1. Let the protection plates remain on the Flange Ball until welding is finished. These
2. Make sure that the Flange Ball is mounted in such a way that the grove is directed
3. If the tank flange is inclined, make sure that the Flange Ball is welded so that the
52
plates protect the surface of the Flange Ball from welding sparks.
A. Protection plate
B. Flange Ball
upwards when the flange is mounted on the tank nozzle.
A. Groove
Flange Ball is horizontal when it is mounted on the tank.
The tank flange inclination should not exceed 17 degrees.
60 mm
< 17°