Emerson Rosemount 5900S Reference Manual page 225

Radar level gauge
Hide thumbs Also See for Rosemount 5900S:
Table of Contents

Advertisement

Reference Manual
00809-0100-5900
Lift-off minimum voltage
9.0 VDC
Device capacitance / inductance
See
Product
Class (Basic or Link Master)
Link Master (LAS)
Number of available VCRs
Maximum 20, including one fixed
Links
Maximum 40
Minimum slot time / maximum response delay/ minimum intermessage delay
8/5/8
Blocks and Execution time
Table A-1: Execution Time
Block
1 Resource block
5 Transducer blocks (Level, Register, Adv_Config, Volume, and LPG)
6 Analog Input (AI)
2 Analog Output (AO)
1 Proportional/Integral/Derivate (PID)
1 Signal Characterizer (SGCR)
1 Integrator (INT)
1 Arithmetic (ARTH)
1 Input Selector (ISEL)
1 Control Selector (CS)
1 Output Splitter (OS)
For more information, see the F
Instantiation
Yes
Conforming F
ITK 6
Field Diagnostics support
Yes
Rosemount 5900S Radar Level Gauge
Certifications.
OUNDATION
Fieldbus
OUNDATION
Specifications and reference data
Fieldbus Blocks Manual.
September 2019
Execution time
N/A
N/A
10 ms
10 ms
15 ms
10 ms
10 ms
10 ms
10 ms
10 ms
10 ms
225