Rosemount 5900C With Parabolic Antenna - Emerson Rosemount 5900C Reference Manual

Radar level gauge
Table of Contents

Advertisement

Reference Manual
00809-0100-5901
A.6.8
Transient / built-in lightning protection
According to IEC 61000-4-5, level 2 kV line to ground. Complies with IEEE 587 Category B
transient protection and IEEE 472 surge protection.
A.6.9
Low Voltage Directive (LVD)
LVD (EU directive 2014/35/EU) EN/IEC 61010-1
A.7

Rosemount 5900C with parabolic antenna

Operating temperature in tank
Max. +180 °C (+356 °F) with FEP O-ring, or +230 °C (+445 °F) with Kalrez
Measuring range
0.8 to 30 m (2.6 to 100 ft) below flange.
Possibility to measure 0.5 to 50 m (1.6 to 164 ft). Accuracy may be reduced. For longer
measuring range, consult your local representative.
Pressure range
Clamped/threaded: -0.2 to 0.2 bar (-2.9 to 2.9 psig)
Welded: -0.2 to 10 bar (-2.9 to 145 psig)
Material exposed to tank atmosphere
Antenna: Material corresponds to AISI 316/316L and EN 1.4401 /1.4404
Sealing: PTFE
O-ring: FEP, or Kalrez
Antenna dimension
440 mm (17 in.)
Manway size and installation
500 mm (20-in.) opening.
The parabolic antenna is installed on the manway cover by using the flange ball. It is
designed for easy adjustment of the antenna inclination and orientation within the
specified limits.
The flexible flange ball can be installed on both horizontal or inclined manways without
any special arrangements.
Tank connection
The gauge is clamped in a 96-mm (3.78-in.) diameter hole, or welded in a 117-mm (4.61-
in.) diameter hole.
Rosemount 5900C Radar Level Gauge
®
Specifications and reference data
September 2019
®
O-ring