5. Maintenance and conversion
1
Manifold
sub-base
2
Guide pins
3
Seal plate
4
Right end plate
Fig. 5/5: Mounting the right end plate
Festo P.BE-VTSA-44-EN en 1101f
1
2
3. Screw the components together with the original hexagon
socket head screws. These screws have a screw head with
gear teeth. Tighten the screws in the sequence 1, 4, 3,
2 at first slightly, then with 3.0 Nm
for position).
4. Mount the valve terminals onto the mounting surface
(see Chapter 2 Mounting, "Wall mounting" or "H-rail
mounting").
5. Then install the pneumatic and electrical connections
(see Chapter 3 "Installation, Connecting the VTSA... valve
terminal").
2
3
. (See Fig. 5/3
(± 10 %)
4
5-17