3. Installation
3.6

Address assignment of the valves

3-44
The VTSA... can be configured with maximum as many valve
positions as there are addresses available (see Chapter 1,
Tab. 1/2 ... Tab. 1/4 under "Max. number of controllable
solenoid coils").
Address allocation (width 18 ... 52 mm)
Counting begins on the valve terminal from left to right
The number of assigned addresses per valve position
depends on the manifold sub-base; it is irrelevant
whether the manifold sub-base is fitted with valves or
cover plates.
Manifold sub-base type VABV-...-T1:
– occupies one address per valve location
Identification features:
– Rating plate with black dot
– Colour of the solenoid coil contact housing in the
manifold sub-base: Red
Manifold sub-base type VABV-...-T2:
– Occupies two addresses per valve position
The following assignment applies:
– Solenoid coil 14 occupies the lower-value address
– Solenoid coil 12 occupies the higher-value address.
Identification features:
– Colour of the solenoid coil contact housing in the
manifold sub-base: Black
Festo P.BE-VTSA-44-EN en 1101f