4. Commissioning
Non-detenting operation of manual override (automatic)
Valve width
18 ... 52 mm
Tab. 4/4:
Non-detenting actuation of the manual override
4-12
Operation
Use a screwdriver
(max. blade width 4 mm)
to press down the
plunger of the manual
override until the valve
switches.
Note on width
18 to 52 mm:
In the case of manual
overrides without a cap, do
not turn the pressed-down
plunger as otherwise the
manual override will lock.
Keep the stem of the MO
pressed.
Release the plunger
(the spring resets the
plunger of the manual
override to the initial
position).
Valve response
The valve:
– moves to the switching position
– remains in the switching position
– returns to the rest position (not for bistable
5/2-way valves (ident. code J, D)