A. Technical appendix
General
1)
Vibration and shock
2)
– Vibration
2)
– Shock
– Continuous shock
1)
For explanations of severity levels, see Tab. A/4
2)
Specifications on vibration and shock of the CPX terminal can be found in the manual for the
CPX system
3)
For requirements for severity level 2, see Tab. A/5
4)
VTSA... valve terminal with more than one vertical stacking component on a valve position:
Severity level 1
Tab. A/3:
Vibration and shock
Severity
Vibration
level
1
0.15 mm travel at 10-58 Hz;
2 g acceleration at 58-150 Hz
2
0.35 mm travel at 10-60 Hz;
5 g acceleration at 60-150 Hz
Tab. A/4:
Values for vibration and shock as per DIN/IEC68
A-6
Tested as per DIN/IEC68 / EN60068 parts 2 - 6
With H-rail mounting: No stress permissible
3) 4)
With wall mounting:
Tested as per DIN/IEC68 / EN60068 parts 2 - 27
With H-rail mounting: No stress permissible
3) 4)
With wall mounting:
Tested as per DIN/IEC68 / EN60068 parts 2 - 29,
With H-rail mounting: No stress permissible
With wall mounting: Severity level 1
Shock
±15 g at 11 ms duration,
5 shocks per direction
±30 g at 11 ms duration;
5 shocks per direction
Continuous shock
±15 g for 6 ms duration;
1000 shocks per direction
-----
Festo P.BE-VTSA-44-EN en 1101f