Error Numbers And Warning Numbers - Festo CPX-CMAX-C1-1 Mounting, Installation And Diagnostics

Cmax axis controller
Hide thumbs Also See for CPX-CMAX-C1-1:
Table of Contents

Advertisement

5. Diagnostics and error handling

5.2.4 Error numbers and warning numbers

Malfunction group 0 Configuration error
CPX error group 100 (CPX−MMI: [Configuration error] )
No.
Message
01
The target configuration
differs from the actual
2)
configuration
02
Unknown valve type
03
Unknown cylinder type
04
Unknown type of dis
placement encoder or
sensor interface
1)
For the error level and reset type, see section 5.2.3.
2)
To avoid tubing errors, the movement test is reset. CMAX has the status C03. The movement test
should be executed again afterwards.
5−8
Cause/description
A component on the axis
string is not part of the
target configuration:
Displacement encoder
or sensor interface
(type, length).
Cylinder (type, length,
diameter).
Valve (size).
The displacement en
coder and the valve have
been exchanged and no
longer match the target
configuration or the
serial numbers have
changed.
Connected valve is not
supported.
Connected cylinder or
the sensor interface is
not supported.
Connected displacement
encoder or the sensor in
terface is not supported.
Error handling
Check component and
·
replace, if necessary
Accept actual con
·
figuration (download).
Check the axis con
·
figuration. Check to
make sure two axis
strings have not been
interchanged.
Exchange the valve or
·
Update firmware.
·
Exchange the cylinder
·
or sensor interface or
Update firmware.
·
Exchange the displace
·
ment encoder or sen
sor interface or
Update firmware.
·
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
1)
Type
Error
level: F2
Reset: N
Error
level: F2
Reset: N
Error
level: F2
Reset: N
Error
level: F2
Reset: N