Safety setting

Wire break
Voltage type
Setpoint
Output pressure drops to 0 bar.
Supply volt-
The last value is saved. The output pressure is maintained but not regulated. In
age
the medium term the pressure at the output can increase or diminish.
Fig. 32
12

Eliminating malfunctions

Cause
– Value fallen below limit value (setpoint value)
– Value exceeded limit value (setpoint value)
– Undervoltage in the 24 V operating voltage
– Overvoltage in the 24 V operating voltage
– Hardware error
– Temperature range exceeded in VPPM-...C1
Fig. 33
Malfunction
Possible cause
VPPM-..C1 not re-
Supply voltage not applied, POWER LED
acting
does not light up
Set value voltage or set value current not
applied
VPPM-... C1 defective
Flow too low
Restriction of the flow cross section due to
connection design (swivel fittings)
Pressure increase
Large cylinder volume and long tubing
too slow
Pressure constant
– Supply cable breakage (the last output
pressure set is maintained but not regu-
despite modified
lated. In the medium term the pressure
setpoint value
at the output can increase or diminish).
specification
– Supply pressure P1 too low
UP/DOWN but-
Voltage is present at digital inputs D1 and
tons on the
D2
VPPM-...C1 do not
react.
Fig. 34
13
Technical data
Note
Certain variants of the product have been certified by Underwriters Laboratories
Inc. (UL) for the USA and Canada. Observe the following if the UL requirements
are to be complied with in your application:
• Rules for observing the UL certification can be found in the separate UL-spe-
cific documentation. The relevant technical specifications listed there also
apply here.
• The technical data in this documentation may show values deviating from this.

General data

Design
Mounting position
Medium
Protection class
Permissible temp. range
– Ambient temperature
– Medium
– Storage
Current type
The last value is saved. The output
pressure is maintained but without
closed-loop control. In the medium
term the pressure at the output can in-
crease or diminish.

Error display

ER.09
ER.10
ER.05
ER.26
ER.01
ER.28
Remedy
• Check the 24 V DC supply
voltage
• Check controller
• Check connection
• Send the device to Festo for
repairs.
• Use an alternative connec-
tion
• Select different parameter
record
• Use larger size VPPM-...C1
• Replace supply cable
• Increase supply pressure
• Apply 0 V DC to digital in-
puts D1 and D2.
Proportional pressure regulator
Any, preferably horizontal
(display components facing upwards)
Compressed air to ISO 8573-1:2010 [7:4:4],
inert gases
Operation with lubricated medium not pos-
sible
IP 65 when mounted, with tightened mount-
ing screws, in connection with plug socket
according to "Accessories".
[°C]
0 ... +50
+10 ... +50
–10 ... +70
General data
Vibration and shock
– Vibration
– Shock
Materials
Housing
Cover
Seals
Lubrication
Weight
Fig. 35

Pneumatics data

Pressure ranges
– Permitted input pressure
– Regulation range
Total leakage when new
Connections
Nominal size
– Pressurisation
– Exhaust
Fig. 36
Data for the electrical components
Electrical connection
Perm. operating voltage
Max. electrical power consumption
– Nominal size 1/8" and 1/4"
– Nominal size 1/2"
Power rating of digital switching out-
put D3 (PIN 8 in el. connection)
Max. perm. supply and signal line
length
Overall accuracy
– Standard (2 %) +0.5 x hysteresis
– Class S1 (1 %) +0.5 x hysteresis
Hysteresis
Voltage type VPPM-...-V1.-...C1
– Setpoint value size
– Input resistance (setpoint value)
– Working resistance of actual value
output
Current type VPPM-...-O4.-...C1
– Setpoint value size [mA]
– Input resistance (setpoint value)
– Working resistance of actual value
output
Electromagnetic compatibility (EMC)
*)
– interference emission and resist-
ance
1) The valve is intended for use in an industrial environment. Outside of industrial environments, e.g. in
commercial and mixed-residential areas, actions to suppress interference may have to be taken.
Fig. 37
The following data does not apply to mount-
ing the VPPM... to the angle bracket VAME-
P1-A.
tested according to DIN/IEC 68/EN 60068
part 2-6;
With wall mounting:
0.35 mm path at 10 ... 60 Hz
5 g acceleration at 60 ... 150 Hz
Checked as per DIN/IEC 68/EN 60068 Part
2-27
With wall mounting:
±30 g at 11 ms duration; 5 shocks per direc-
tion
Wrought aluminium alloy
PAXMD6-GF50/gr-P, PA6-GB20,GF10/gr-P
Nitrile rubber
Silicone-free
[g]
1/8": 400
1/4": 560
1/2": 2050
2 bar type
6 bar type
30 psi
90 psi
[bar]
0 ... 4
0 ... 8
0.02 ... 2
0.06 ... 6
Supply pressure p1 at least 1 bar over output
pressure p2
[l/h]
< 5
G1/8" (1/8 NPT), G1/4" (1/4 NPT),
G1/2" (1/2" NPT)
[mm]
With 1/8": 6
With 1/4": 8
With 1/2": 12
With 1/8": 4.5
With 1/4": 7
With 1/2": 12
2 bar type
6 bar type
30 psi
90 psi
Pin contact M12x1, 8-pin
[V DC]
21.6 ... 26.4 V DC (perm. residual ripple
max. 10 %)
[W]
7
12
[mA]
Max. 60
[m]
10
[bar]
0.045
0.135
0.025
0.075
0.5 % Full scale
[V DC]
0 ... +10
[kΩ]
10
[kΩ]
Min. 2
[mA]
4 ... 20
[Ω]
250
[Ω]
max. 500
See declaration of conformity
www.festo.com
CE conformity for industrial installations ful-
filled.
10 bar
type
150 psi
0 ... 11
0.1 ... 10
10 bar
type
150 psi
0.225
0.125