Property index of the gate
8.4.3.3.
Different forms of gate have different properties and the properties are defined by index below:
Pass band ripples and sidelobe level: to descript the gate form.
Cut-off time: it is the time between end time of the gate (at -6dB of the filter edge) and the first sidelobe peak point.
Minimum gate span: it equals to end time minus start time and it is twice of the cut-off time.
Gate Form
Pass Band Ripple
Min.
Standard
Width
Max.
Each form of gate has a recommended minimum gate span to operate correctly, which is determined by limited cut-off ratio of the
gate. If the gate span set is smaller than this minimum value, the Analyzer will produce effects below:
The gate form is distorted, without pass band.
Indication of start and end time is incorrect.
Sidelobe level would be increased.

8.5.Time Domain Measure Data

This section will provide examples of various Measure types to facilitate understanding of time domain response of the measured
piece.

8.5.1. Screening

Screening will affect the response observed during time domain Measure; therefore, when explaining time domain Measure data,
what is screening and its effect toward Measure result must be known clearly.
Screening occurs when discontinuous points or loss nearest to reference plane affects response of each discontinuous point.
Energy reflected or absorbed by the first discontinuous point won't approach the subsequent discontinuous points.
Response of each subsequent discontinuous point is smaller than that without screening.
Screening caused by energy reflection
8.5.1.1.
With serious mismatch, screening by energy reflection happens, examples below illustrate such phenomenon:
When a section of 50Ω transmission line is connected with a section of 25Ω air line and connected with another 50Ω
Fig.8-12 Sidelobe Level of Different Gates
Table 8-1 Property Index of Different Gates
Sidelobe Level
±0.10dB
±0.01dB
±0.01dB
±0.01dB
Cut-off Time
-48dB
1.4/frequency span
-68 dB
2.8/frequency span
-57 dB
4.4/frequency span
-70 dB
12.7/frequency span
131
Tel: 886.2.2175 2930 Email: sales@salukitec.com
Min. Gate Span
2.8/frequency span
5.6/frequency span
8.8/frequency span
25.4/frequency span