10.6

Pulse frequency and current reduction

Relationship between pulse frequency and output base-load current reduction
Table 10- 5
Rated power
based on LO
The permissible motor cable length depends on the cable type and the chosen pulse frequency.
1
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG
Current reduction depending on pulse frequency
Rated output current at pulse frequency of
4 kHz
0.37 kW
1.30 A
0.75 kW
2.2 A
1.1 kW
3.1 A
1.5 kW
4.1 A
2.2 kW
5.6 A
3.0 kW
7.3 A
4.0 kW
8.8 A
10.6 Pulse frequency and current reduction
6 kHz
8 kHz
10 kHz
1.11 A
0.91 A
0.78 A
1.9 A
1.5 A
1.3 A
2.6 A
2.2 A
1.9 A
3.5 A
2.9 A
2.5 A
4.8 A
3.9 A
3.4 A
6.2 A
5.1 A
4.4 A
7.5 A
6.2 A
5.3 A
Technical data
1
12 kHz
14 kHz
0.65 A
0.59 A
1.1 A
1.0 A
1.6 A
1.4 A
2.1 A
1.8 A
2.8 A
2.5 A
3.7 A
3.3 A
4.4 A
4.0 A
16 kHz
0.52 A
0.9 A
1.2 A
1.6 A
2.2 A
2.9 A
3.5 A
311