Advanced commissioning

6.2 Inverter control
Figure 6-3
6.2.2.1

Digital Inputs

Changing the function of the digital input
Table 6- 1
BI
p0810 Command data set selection CDS bit 0
p0840 ON/OFF1
p0844 OFF2
p0848 OFF3
p0852 Enable operation
p0855 Unconditionally release holding brake
p0856 Enable speed controller
p0858 Unconditionally close holding brake
p1020 Fixed speed setpoint selection bit 0
p1021 Fixed speed setpoint selection bit 1
132
Internal interconnection of the inputs and outputs
Binector inputs (BI) of the inverter (selection)
Significance
Interconnect the status parameter of the digital input
with a binector input of your choice.
Interconnecting signals in the inverter (Page 322)
Binector inputs are marked with "BI" in the parameter
list of the List Manual.
BI
Significance
p1036 Motorized potentiometer, setpoint, lower
p1055 Jog bit 0
p1056 Jog bit 1
p1113 Setpoint inversion
p1201 Flying restart enable signal source
p2103 1. Acknowledge faults
p2106 External fault 1
p2112 External alarm 1
p2200 Technology controller enable
p3330 Two-wire/three-wire control, control
command 1
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG