Installation
4.3 Electrical Installation
Figure 4-13
Daisy chaining power between Inverters
4.3.6

Connecting the PROFINET interface

Industrial Ethernet Cables and cable length
Listed in the table below are the recommended Ethernet cables.
Table 4- 7
Cable type
Industrial Ethernet FC TP Standard Cable GP 2 x 2
Industrial Ethernet FC TP Flexible Cable GP 2 x 2
Industrial Ethernet FC Trailing Cable GP 2 x 2
Industrial Ethernet FC Trailing Cable 2 x 2
Industrial Ethernet FC Marine Cable 2 x 2
74
Recommended PROFINET cables
Max. length be-
tween devices
100 m (328 ft)
85 m (278 ft)
85 m (278 ft)
85 m (278 ft)
85 m (278 ft)
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG
Article Number
6XV1840-2AH10
6XV1870–2B
6XV1870–2D
6XV1840–3AH10
6XV1840–4AH10