Collecting motor data

The SINAMICS G110M system is generally delivered as a completely assembled, Inverter,
Power Module and motor, but it may be necessary to input specific motor data depending on
the requirements of the users application. All the necessary motor data is displayed on the
motor rating label as shown in the following example.
Figure 5-1
1
2
3
4
5
6
7
8
9
10 Customer ID
11 Oil quantity [l] main gearbox / intermediate gearbox
12 Type of oil
13 Oil viscosity ISO VG class according to DIN 51519 / ISO 3448
14 Total transmission ratio i
Frequency 1
15 Rated frequency f [Hz]
16 Gearbox output speed n
17 Geared motor output torque T
18 Service factor f
Frequency 2
19 Rated frequency f [Hz]
20 Gearbox output speed n2 [rpm]
21 Geared motor output torque T2 [Nm]
22 Service factor f
Motor data
23 Phase number and type of current for the motor
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG
SIMOGEAR motor rating label example
Matrix code
Applied standard
Serial No.
FDU = Siemens AG, Bahnhofstr. 40, 72072 Tübingen, Germany
CE marking or other marking, if required
Article No.
Model - Type - Size
Mounting position
Degree of protection according to IEC 60034-5 or IEC 60529
Weight m [kg]
B
B
[rpm]
2
[Nm]
2
Commissioning
5.2 Prepare basic commissioning
97