Siemens SINAMICS G110M Operating Instructions Manual page 72

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Installation
4.3 Electrical Installation
Terminal housing mains supply connections
Type: HAN Q4/2 (Input and
Output), 3 AC 380 V (-10%)
... 480 V (+10%)
Important:
The pinouts refer to the ac-
tual connectors on the ter-
minal housing.
The terminal designation
X1/3 is used because the
mains input and output can
be swapped around depend-
ing on which side of the
terminal housing the CPI is
mounted.
Internal motor and power connection
The internal motor and power connections on the G110M system are located inside the
Control Unit and motor housing. The connections are shown in the following figure.
Figure 4-12
72
Control Unit motor and power connections
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG