Installation
4.2 System Installation
16. Final connection and adjustments
17. PROFIBUS / USS address and basic commissioning DIP-
18. PROFIBUS / USS network termination switch
19. Fit memory card into the Power Module
52
1. Connect the temperature sensor connector into the
connector at the top edge of the CPI.
2. Connect the small communications connector into the
connector at the top of the CPI.
3. Connect the large communications connector into the
connector on the top of the Control Module.
4. Connect the CPI ribbon cable to the connector on the top of
the Control Module.
5. Configure the DIP switches to the requirements of the
application (see Step 17 below).
Note:
The PROFIBUS/PROFINET communications cable is not pre-
fitted to the Control Module, it is part of the accessories sup-
plied in the product packaging.
switches
There are three sets of DIP-switches that allow the user to
configure the network device address and perform a basic
commissioning of the system.
Basic Commissioning with DIP switches (Page 104)
When using the PROFIBUS or USS communications proto-
cols, the last converter on the network must have the network
termination switch in the ON position.
To allow parameter settings to be stored or copied to the con-
verter, the memory card must be fitted into the memory card
reader.
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG