Advertisement

Alarms, faults and system messages
9.5 Identification & maintenance data (I&M)
Table 9- 4
PROFINET LED
LNK - On
LNK - Off
Table 9- 5
Flashing -RED
Flashing -
RED/YELLOW
Flashing -
GREEN/RED
RED
GREEN
9.5
Identification & maintenance data (I&M)
I&M data
The inverter supports the following identification and maintenance (I&M) data.
I&M
data
I&M0
I&M1
I&M2
I&M3
I&M4
When requested, the inverted transfers its I&M data to a higher-level control or to a PC/PG
with installed STEP 7, STARTER or TIA-Portal.
296
Description of PROFINET communications LED
Description of function
Link is active
Link inactive with no data being transferred
Description of AS-i communications LED
AS-i/FLT
Description of function
No communications between processors within the converter
Slave address 0
Converter trip
AS-i master not connected
System OK
Format
Explanation
u8[64] PROFIBUS
Inverter-specific data, read only
u8[54] PROFINET
Visible String [32]
Plant/system identifier
Visible String [22]
Location code
Visible String [16]
Date
Visible String [54]
Any comment
Octet String[54]
Check signature to track chang-
es for Safety Integrated.
This value can be changed by
the user.
The test signature is reset to the
value generated by the machine
is p8805 = 0 is used.
Associated
parameters
-
p8806[0 ... 31]
p8806[32 ... 53] "sc2+or45"
p8807[0 ... 15]
p8808[0 ... 53]
p8809[0 ... 53]
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 06/2016, FW V4.7.6, A5E31298649B AG
Example for the
content
See below
"ak12-
ne.bo2=fu1"
"2013-01-21
16:15"
-
Values of
r9781[0] and
r9782[0]