Installation
4.2 System Installation
7. Connect the motor temperature sensor
8. Connecting the mains earth cable (HANQ variant)
48
Connect the EM brake cables to the EM brake terminals
1. Connect the EM brake cables to the EM brake terminal
block.
2. Connect the EM brake cables to the EMB+ and EMB-
terminals on the terminal block.
Notes:
• Ensure that the cable is routed under the cable clamp.
• The terminals can accept cable to a maximum size of 4
mm
.
2
• The EM brake is an optional extra which is ordered
separately.
1. Connect the motor temperature sensor cables to the
temperature sensor terminal block.
2. Ensure that the cable is clear of any obstructions and does
not restrict access to other cables and connectors within the
Terminal Housing.
Connect the motor temperature sensor (second part)
1. Connect the second part of the motor temperature sensor
cable to the temperature sensor terminal block.
2. The connector on the second part of the motor temperature
sensor is plugged into the Communications and Power
Interface (CPI).
Notes:
• The motor temperature sensor terminal block has a
diameter of 2.79 mm.
• The final connection of the temperature sensor cannot be
completed until the CPI has been fitted. This will be done
after the CPI is fitted, as shown later in this procedure.
1. Connect the HANQ earth connection to the earthing post of
the Terminal Housing.
2. Tighten the earthing post screw to 1.5 Nm.
Note:
If the SINAMICS G110M is ordered as a complete system,
then all mechanical and electrical installation is completed in
the factory prior to delivery.
Distributed converter for SIMOGEAR geared motors