Avaya Definity SI Maintenance Manual page 2241

Table of Contents

Advertisement

RDIG-STA (Remote Digital Station)
ID Request Test
station sends its configuration information and health information back.
This information is checked and a pass/fail result is provided.
Ringer Update
to the processor records.
DTMF Administration Update
refresh the default value that causes the station to send touch- tones only
in the primary information channel. This value is set initially when the
station is put in-service and every time the station's state changes from
other states to in-service.
Table 10-552. TEST #17 Station (Digital) Audits Test
Error
Test
Code
Result
1
ABORT
2
ABORT
3
ABORT
4
ABORT
5
ABORT
555-233-123
A request is made to the station for its status. The
This updates the digital telephone ringer state according
This is a message to the digital station to
Description/Recommendation
Switchhook audit timed out.
1. Make sure voice terminal is connected and repeat
test.
2. If test fails, replace voice terminal and repeat test.
ID request fails, health bit returned from voice terminal is bad.
1. Make sure voice terminal is connected and repeat
test.
2. If test fails, replace voice terminal and repeat test.
The EPF has detected an overcurrent condition.
1. Use test UUCSSpp long. If Test #11 passes, then the
EPF condition was cleared. Rerun the Short Test
Sequence. If Test #11 does not pass, follow the repair
procedures described for Test #11.
2. Look for Error Type 769 logged against RDIG-STA
and follow the procedures in the associated footnote.
If any additional problems are found, rerun the test.
Internal system error
1. Resolve any outstanding circuit pack maintenance
problems.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
Ringer update aborted due to station being in ready-for-service
or out-of-service state.