1
Spot Welding Application Using a Motor Gun
1.8
Dry Spot (Motor Gun)
As for a value to "7", set a value so that the following equal-
ity to be true.
1000 <= 1ST to 4TH PRESS
NOTE
If the gun pressure is not set following the above mentioned
instructions, the actual pressure over the specified pressure
cannot be guaranteed.
Operating procedure
1. Select {SPOT WELDING} on the {Main Menu}.
2. Select {PRESSURE}.
– Pressure window appears.
3. Select a file No. by pressing [PAGE].
4. Select an item to be set.
5. Enter a numerical value, and press [ENTER].
– To {PRESS UNIT}, press [SELECT] to display "N" and
"% (TORQUE)" alternately.
– To {OUT} item, press [SELECT] to display "ON" and "OFF"
alternately.
1-69