YASKAWA YRC1000 Operator's Manual page 74

Or spot welding using motor gun
Hide thumbs Also See for YRC1000:
Table of Contents

Advertisement

1
Spot Welding Application Using a Motor Gun
1.7
Welding Instruction (SVSPOT Instruction)
3. Select a file number by pressing [PAGE].
4. Select an item to be specified.
5. Input a numeric value and press [ENTER].
– For {END CONDITION}, "PRESS TIME" and "END WAIT" alternate
each time [SELECT] is pressed.
6. Move the cursor to {SETTING} and press [SELECT].
– "DONE" appears to this item.
Table 1-3: <Example>
1ST PRESS
2ND PRESS
3RD PRESS
4TH PRESS
Pressure
Weld Complete
NOTE
PRESS (N)
2000
1500
2200
1800
0.2
0.1
0.2
2000
2200
1000
1500
1800
Gun pressure can be edited during the playback operation.
The edited content is reflected after the gun pressure set-
ting is done.
1-64
END CONDITION
PRESS TIME
0.20 sec
PRESS TIME
0.10 sec
PRESS TIME
0.20 sec
END WAIT
-
t