1
Spot Welding Application Using a Motor Gun
1.4
System Setting (Motor Gun)
7. THICKNESS DETECTION FUNCTION
Set "VALID" or "INVALID" of the THICKNESS DETECTION FUNCTION.
Refer to chapter 1.13.7.4
8. THICKNESS ERROR NOTICE
Set the action when the thickness error occurs.
ALARM:
Raise an alarm when the thickness error occurs.
SIGNAL: Outputs the universal signal for 100msec pulse instead of
raising an alarm.
9. THICKNESS ERROR NOTICE GOUT#
When setting the "SIGNAL" at the "8. THICKNESS ERROR NOTICE",
this item is displayed. Set the universal signal to output when the thick-
ness error occurs. If "0" is set, the signal is not outputted.
10. THICKNESS CHECK MODE SELECT GIN#
Set the universal signal No. to switch to the THICKNESS MEASURE
MODE. Setting the value except "0" validates this item. If validated,
unable to switch to the THICKNES MEASURE MODE by using the pro-
gramming pendant.
11. THICKNESS ALARM IGNORE GIN#
Set the universal signal No. to ignore the THICKNESS DETECTION
function.
Setting the value except "0" validates this item.
12. WELD GROUP NUMBER
Set the maximum value of the group number when performing the group
output to the welder.
Refer to chapter 1.13.7
13. WELD GROUP ORIGINAL NO.
Set the signal outputting method when performing the group output to
the welder.
Select from the two methods below.
0 Origin:
The set value in the group output number (WGO tag) minus
1 is outputted as the signal.
1 Origin:
The set value in the group output number (WGO tag) is
outputted as the signal.
Refer to chapter 1.13.7
more details.
14. WELD COMPLETE DETECT METHOD
Set the detection method of the weld complete signal, which is inputted
from the welder.
Select form the two conditions below.
BIT UP:
Rising the signal is regarded as the completion of the
welding.
STATUS: It is regarded as the completion of the welding, when
the status of the signal is ON. If the weld complete
signal is already turned ON at the beginning of the
welding instruction, the welding instruction will be
terminated immediately.