The setting items are as follows:
[Additional]
Set the additional ARP announcement.
Enable the additional ARP announcement. The ARP is sent at 1, 2, 4, 8 and 16 seconds after the
link up/DHCP assignment.
Disable the additional ARP announcement. The ARP is only sent at 1 second after the link up/
DHCP assignment.
[Periodic]
Set the interval of the ARP announcement in the range of 0 to 600 seconds.
Initial setting: 0
•
The function is disabled if you set it to 0.
[USB]
Set the USB connection.
The setting items are as follows:
[Flow Control]
Set the communication protocol.
The options are as follows:
•
[STATUS4]
•
[STATUS5]
•
[NONE]
[BCC]
Enable or disable the BCC check function.
Appears only if you have selected [STATUS5] in the [Flow Control] menu.
[Change USB Serial]
Set the type of the USB serial number that the printer returns.
Returns the USB serial number (00000000).
This option is suitable when you want to replace the printer without adding a new printer driver.
To do so, you need to set this setting to enabled before installing the printer.
261