SATO FX3-LX Operator's Manual page 231

Hide thumbs Also See for FX3-LX:
Table of Contents

Advertisement

1. Use the following formula to calculate the slice level:
(High level - Low level) x 0.3 + Low level = slice level
2. Tap [GAP Slice Level] in the [Calibrate] menu.
3. Change the [Gap Slice Level] value. Set the [Gap Slice Level] to the level calculated in step 1.
4. Tap
to confirm the value.
If you set the [Gap Slice Level] to 0.0 (V), the printer sets the slice level automatically.
[I-Mark Levels]
Manually set the I-mark sensor level.
The setting procedure is as follows:
First, adjust the "Low" level (voltage) of the I-mark sensor.
1. Pass the media (attached with liner) above the I-mark sensor. Align it so that the I-mark sensor
does not detect the I-mark (black mark).
2. Close the top cover. To get the correct adjustment result, adjust after you have closed the top
cover.
3. Tap [I-Mark Levels] in the [Calibrate] menu.
4. Change the [Emit] value until the [Sensor] value is below 0.5 (V). Set the [Emit] value as low as
possible.
5. If the [Sensor] value does not decrease below 0.5 after you changed the [Emit] value, change the
[Receive] value.
6. Take a note of the [Sensor] value from the above procedure. This is the "Low" level value for the I-
mark sensor.
Next, check the "High" level (voltage) of the I-mark sensor as follows:
1. Pass the media above the I-mark sensor so that the I-mark sensor can detect the I-mark (black
mark).
2. Close the top cover.
3. Check the [Sensor] value.
If the value is 1.0 (V) higher than the "Low" level value you have recorded, this is the "High" level
value for the I-mark sensor.
If the difference between the "High" and the "Low" levels is less than 1.0, adjust the [Emit] and
[Receive] values so that the difference is more than 1.0, or adjust the "Low" level (voltage) of the I-
mark sensor again.
4. If both "High" and "Low" levels comply with the standard value, tap
The standard values for the "High" and "Low" levels for the I-mark sensor are as follows:
Low (without I-mark) < 0.5 (V)
High (with I-mark) - Low ≥ 1.0 (V)
[I-Mark Slice Level]
Set the I-mark sensor slice level.
231
to confirm the value.

Advertisement