SATO FX3-LX Operator's Manual page 232

Hide thumbs Also See for FX3-LX:
Table of Contents

Advertisement

The setting procedure is as follows:
1. Use the following formula to calculate the slice level:
(High level - Low level) x 0.7 + Low level = slice level
2. Tap [I-Mark Slice Level] in the [Calibrate] menu.
3. Change the [I-Mark Slice Level] value. Set the [I-Mark Slice Level] to the slice level calculated in
step 1.
4. Tap
to confirm the value.
If you set the [I-Mark Slice Level] to 0.0 (V), the printer sets the slice level
automatically.
[Dispenser Levels]
Manually set the dispenser sensor level.
Does not appear when the optional cutter kit or partial kit is installed.
The setting procedure is as follows:
First, adjust the "Low" level (voltage) of the dispenser sensor.
1. Remove the media.
2. Tap [Dispenser Levels] in the [Calibrate] menu.
3. Change the [Emit] value until the [Sensor] value is below 0.5 (V).
Set the [Emit] value as low as possible.
4. If the [Sensor] value does not decrease below 0.5 after you changed the [Emit] value, change the
[Receive] value.
5. Take a note of the [Sensor] value from the above procedure. This is the "Low" level value for the
dispenser sensor.
Next, check the "High" level (voltage) of the dispenser sensor as follows:
1. Load the media.
2. Close the top cover.
3. Check the [Sensor] value.
If the value is 1.0 (V) higher than the "Low" level value you have recorded, this is the "High" level
value for the dispenser sensor.
If the difference between the "High" and the "Low" levels is less than 1.0, adjust the [Emit] and
[Receive] values so that the difference is more than 1.0, or adjust the "Low" level (voltage) of the
dispenser sensor again.
4. If both "High" and "Low" levels comply with the standard value, tap
The standard values for the "High" and "Low" levels for the dispenser sensor are as follows:
Low (without media) < 0.5 (V)
High (media loaded) - Low ≥ 1.0 (V)
232
[Advanced]
to confirm the value.