Acke Operations - NEC mPD780208 Subseries User Manual

8-bit single-chip microcontrollers
Table of Contents

Advertisement

SCK0
SB0/SB1
ACKE
SCK0
SB0/SB1
ACKE
SCK0
SB0/SB1
ACKE
SCK0
SB0/SB1
ACKE
238
CHAPTER 13 SERIAL INTERFACE CHANNEL 0
Figure 13-22. ACKE Operations
(a) When ACKE = 1 upon completion of transfer
1
2
D7
D6
(b) When set after completion of transfer
6
7
8
9
D2
D1
D0
(c) When ACKE = 0 upon completion of transfer
1
2
D7
D6
(d) When ACKE = 1 period is short
D2
D1
D0
User's Manual U11302EJ4V0UM
7
8
9
D2
D1
D0
ACK
When ACKE = 1 at this point
ACK
If set during this period and ACKE = 1
at the falling edge of the next SCK0
7
8
9
D2
D1
D0
When ACKE = 0 at this point
If set and cleared during this period
and ACKE = 0 at the falling edge of SCK0
ACK signal is output
at 9th clock
ACK signal is output for
a period of one clock
just after setting
ACK signal is not output
ACK signal is not output