The FF valid at TOF option determines whether the printer will perform a
Form Feed when the host sends a Form Feed command, if the printer is at
the top of form.
Disable
Enable
Factory Default
Application > P-SERIES XQ Setup
IMPORTANT
The P-SERIES XQ Setup submenu will only be present when the LP+ Emulation
menu is set to P-SERIES XQ. Otherwise, this menu will be replaced with the LP+
Emulation menu.
IMPORTANT
This LP+ emulation does not have any specific Character Group or Character
Set selection.
Application > P-Series XQ Setup > Horizontal DPI
This feature enables the thermal printer to print images as close as possible
to the same size as those originally programmed for a line matrix or laser
printer by selecting a horizontal resolution that matches that of the printer
that the file was originally generated for.
Although the range allows a selection of up to 400 dpi, the T800 is capable of
printing up to 203 dpi or 300 dpi horizontal resolution, depending on the print
head installed.
Minimum
Maximum
Factory Default
Application > P-Series Setup > FF valid at TOF
Will not perform a form feed when the host sends a
Form Feed and the printer is at the top of form.
Performs a form feed when the host sends a Form
Feed and the printer is at the top of form.
Enable
60
400
120