Printronix Auto ID T800 Series Administrator's Manual page 105

Table of Contents

Advertisement

Host IO > Serial Port > Baud Rate
Sets the baud rate of the serial interface in the printer. Baud rate is the speed
at which serial data is transferred between the host computer and the printer.
600, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
Selections
and 115200 baud.
Factory Default
9600 baud
If you select a baud rate that is greater than 19200
and you experience data loss, you may need to
IMPORTANT
lower the baud rate. You also may need to
increase the Buffer (Kbytes) parameter to improve
performance.
Host IO > Serial Port > Word Length
Sets the length of the serial data word. The length of the data word can be
set to 7 or 8 bits and must match the corresponding data bits setting in the
host computer.
7
7 bit data word
8
8 bit data word
Factory Default
8
Host IO > Serial Port > Stop Bits
Sets the number of stop bits in the serial data word. Either 1 or 2 stop bits
can be selected. The setting must match the corresponding stop bit setting
in the host computer.
1
1 stop bit
2
2 stop bits
Factory Default
1
Host IO > Serial Port > Parity
The options are Odd, Even, Mark, Sense, or None. The setting must match
the corresponding parity setting in the host computer.
Factory Default
None