Sensors > Calibrate > Power-Up Action
Calibration activities when the printer is powered up.
Disable
No activities at power up.
Auto Calibrate is performed at power-up. Once the
Auto Calibrate is complete, the printer will momentarily
Auto-Cal
display the Sensed Distance determined by the Auto
Calibrate.
Assumes user has already calibrated media and used
gap/mark sensor. This moves the media to
Seek TOF
Top-of-Form at power up if Sensors > Control >
Gap/Mark Sensor is not set to Disable.
Factory
Auto-Cal
If Media > TOF >Ticket Save Mode is set, Auto-Cal
IMPORTANT
and Seek TOF will not be performed.
SENSORS > Calibrate > HeadClose Action
Selects whether the printer performs a selected action after a print head open
fault condition is cleared.
No media motion after a print head open fault condition
Disable
is cleared.
Performs Auto Calibration every time the print head
Auto-Cal
open fault condition is cleared.
Moves the media to TOF (Top Of Form) when the
printhead is closed unless Sensors > Control >
Seek TOF
Gap/Mark Sensor is set to Disable.. The media should
already be calibrated using Gap/Mark sensor.
Factory
Disable
If Media > TOF > Ticket Save Mode is set, Auto-Cal
and Seek TOF will not be performed.
IMPORTANT
If there is data pending (data in buffer) when the
head open fault is cleared, Auto-Cal and Seek TOF
are ignored.
83