Table 27. General PTX_SETUP Commands
Command
Sub-Command
DELETE
UPLOAD
DOWNLOAD
OVERLAY
RESET
GET_NAMES
SET_NAME
CLEAR_NAMES
MPI_SELECT
Parameter
Deletes Configuration number Cfg.
Cfg
Cfg must be in the range of 1-8.
This command uploads the
Port;Cfg
configuration stored in location Cfg
to the port specified by Port. Port
must either be 1284 or SERIAL. Cfg
may be 1-8 or ALL.
This command saves the
Cfg
configuration data that follows as
configuration Cfg. Cfg must be 1-8
or END.
This command overlays the
Cfg
configuration data that follows on
existing configuration Cfg. Cfg
must be 1-8 (or END). If Cfg does
not exist then command is treated
the same as DOWNLOAD.
Reboots the printer.
"Port"
This command uploads the names
of the configurations to the port
specified by Port. Port must either
be "1284" or "SERIAL".
This command downloads a name
Cfg
for the configuration specified by
Cfg. Cfg must be 1-8.
This command resets all of the
configuration names to their default
values.
This command selects the active
MPI
Management Protocol Interface
(MPI). Currently there are two
selections "UCP" and "PXML".
Description