Application > P-Series XQ Setup > Define LF Code
This option controls the action of the printer when it receives a Line Feed
code (0A hex) from the host computer. If this feature is enabled, each time
the printer receives a line feed, it inserts an additional carriage return code
(0D hex) into the data stream. Do not use this feature if the host computer
sends carriage returns to the printer.
Does not insert a carriage return before each line feed.
LF = LF
The next print position will be the current print position
of the next line.
Inserts an extra carriage return before each line feed.
LF = CR + LF
The next print position will be print position 1 of the
next line.
Factory Default
LF = CR + LF
Application > P-Series XQ Setup > Control Code 06
Control Code 06 defines the function of ASCII code 06 hex (ACK). You can
select an alternate line spacing of 6.0, 8.0, or 10.3 LPI.
Selections
6.0, 8.0, or 10.3 LPI
Factory Default
8.0 LPI
Application > P-Series XQ Setup > Compressed Print
Controls which host command enables compressed printing.
Char 01 SOH
Char 03 ETX
Char 09 HT
Factory Default
Char 01 SOH
Application > P-Series XQ Setup > Elong/Alt. Font
Controls which host command sets elongated (double high) fonts and
extended character set.
ELNG=BS
Elongated set by BS (08 hex), extended character set
FONT=SO
set by SO (0E hex).
ELNG=SO
Elongated set by SO (0E hex), extended character set
FONT=BS
set by BS (08 hex).
Factory Default
Elng=BS FONT=SO