Reset
Th is function is used to set the measurement values to zero.
When the speed error status is established, it releases the error.
In the wait to go past reference point status, it releases the status. However, in the wait to go past reference
point status for master calibration, it does not release this status, and a mode error results.
Set
This command initiates reset.
Command format
Return format
Target
Examples of use
Compatible command
MG40 Series
SVZ Designated axis
Execution results
Designated axis, MG42 hub unit, all axes
SVZ[00A]
Transmission :
(Reset axis A for the MG41 main unit.)
Return
: OK000
(Successfully completed.)
SVZ[03
]
Transmission :
(Reset all the axes for the MG42 hub unit ID03.)
Return
: OK000
(Successfully completed.)

SVZ[
]
Transmission :
(Reset all the axes for the system.)
Return
: OK000
(Successfully completed.)
Designated axis RES
Measurement
Ethernet
mode
CC-Link
4-5
(E)