Numbers in the A0's: Main unit hardware-related errors
A0
Communication timeout
A1
Communication error
A2
Power supply error
A4
Version mismatch
A5
Save setting value memory error
Numbers in the B0's: Hub unit hardware-related errors
B0
Communication timeout
B1
Communication error
B2
Power supply error
Numbers in the C0's: Measuring unit-related errors
C0
Communication error
C1
System error
6-2
(E)
Communication has timed out.
A disconnected cable, broken cable, power supply trouble or
equipment failure may be to blame.
Th ere is an error in what has been communicated.
Noise, cable trouble or an equipment failure may be to blame.
Th e supply voltage is insuffi cient.
Check the power supplies.
Th e version combination does not enable operation.
Th e settings were initialized to the factory settings due to errors
in the contents of the memory where the setting values were
saved.
Communication has timed out.
A disconnected cable, broken cable, power supply trouble or
equipment failure may be to blame.
Th ere is an error in what has been communicated.
Noise, cable trouble or an equipment failure may be to blame.
Th e supply voltage is insuffi cient.
Check the power supplies.
Measuring unit has detected an error in the communication
system.
Measuring unit has detected system trouble.