4-4. Setup Commands

Output resolution
Th is function is used to set and acquire the output resolution.
A value lower than the input resolution cannot be set for the output resolution.
When STD2 serves as the Area of use setting, the value in parentheses ( ) is used as the output resolution
setting.
Th e scale diff ers between JPN/STD1 and STD2. When the setting has been established for an area with a
diff erent scale, the setting values related to the output resolution will be restored to the factory statuses.
Set
The command sets the output resolution.
Command format
Return format
Target
Save setting values
Examples of use
Compatible command
Acquire
The command acquires the output resolution.
Command format
Return format
Target
Examples of use
Compatible command
4-18
(E)
Setup
mode
OPR Designated axis =<Polarity><Resolution>
<Polarity>
<Resolution>
(Input resolution
Output
resolution)
Execution results
Designated axis
Setting values saved.
OPR[00A]=
Transmission :
Return
: OK000
Designated axis SDR=<Polarity><Resolution>
Setup
mode
OPR Designated axis ?
OPR Designated axis =<Polarity><Resolution>
<Polarity>
<Resolution>
Designated axis
OPR[00A]?
Transmission :
Return
: OPR[00A]=3
Designated axis SDR?
Ethernet
 : Plus
 : Minus
1 : 0.1 μm (0.000005")
2 : 0.5 μm (0.00001")
3 : 1 μm (0.00005")
4 : 5 μm (0.0001")
5 : 10 μm (0.0005")
0.00002" when the input resolution is 0.5 μm
3
Measurement
Ethernet
mode
 : Plus
 : Minus
1 : 0.1 μm (0.000005")
2 : 0.5 μm (0.00001")
3 : 1 μm (0.00005")
4 : 5 μm (0.0001")
5 : 10 μm (0.0005")
0.00002" when the input resolution is 0.5 μm
CC-Link
(Factory setting:
Same as for the
input resolution
setting)
CC-Link
MG40 Series